show bay


Displays the current power and temperature status of a bay.

Syntax: show bay baynum [# fans] [server-registrations] [controllers] [all]

baynum

The number of the bay for which to show status.

server-registrations

Displays the servers in the specified bay.

controllers

Displays status for all Bay Controllers in an Avici router for all bays.

all

Displays status for all bays in a multibay configuration.

Description: The show bay command displays information related to the bay depending upon the keyword associated with the command. If no optional keyword is specified, the power and temperature statistics are provided.

Use the show bay server-registrations command to display server registration information for each server installed in the bay.

Factory Default: None.

Command Mode: Executive

Example 1: The following is sample output from the show bay command:

router#show bay 1

CLEI code for the bay 1 is IPBABB0BRA.

BAYCONTROLLER 1/1:

Administratively active; Current state is active

Max number of historical logging files: 5

Bay Controller's CLEI Code is IPC2T70EAA

  Temperature thresholds (deg C):

Critical Major Minor

-------- ----- -----

Bay 60 50 45

Module 73 69 65



Bay Controller 1/2:

Administratively active; Current state is passive

Max number of historical logging files: 5

Bay Controller's CLEI Code: IPC2T70EAA

  Serial Number: SANSAB0009

  Ipriori release version: Release x.x.x

  Serial Number:

  Operational image version:

  ROM Version: Ipriori Bootrom Release x.x.x built month, day, year, time



Temperature thresholds (deg C):

Critical Major Minor

-------- ----- -----

Bay 60 50 45

Module 73 69 65



POWER:

Line Volts Status Breaker

------ ----- ------- -------

1A 5 inSpec closed

1B 5 inSpec closed

2A 5 inSpec closed

2B 5 inSpec closed

3A 5 inSpec closed

3B 5 inSpec closed

4A 5 inSpec closed

4B 5 inSpec closed



LINKS:

Link Status

-------- ------

Ethernet up

HDLC up



FANS:

Fan's CLEI Code is IPC2U80EAA

Fan AdminState OperState RPM degC LedState

--- ---------- --------- ---- ---- --------

1 controlled controlled 2432 22 off

2 controlled controlled 2432 22 off

3 controlled controlled 2432 21 off

4 controlled controlled 2400 21 off

The following table describes the fields in the display:

Table 3-8. Fields Displayed by show bay 
Field Description

CLEI Code for bay x

Specifies the Common Language Equipment Identification (CLEI) Code assigned by Telcordia for this bay.

BAYCONTROLLER
[1|2]

Identifies the bay controller.

administrative state

A bay controller can be in a state of:

  • reboot - bay controller is rebooting

  • passive - bay controller is in passive operation

  • active - bay controller is in active operation

current state is

The state of a bay controller can be

  • passive - bay controller is in passive operation

  • active - bay controller is in active operation

  • failed - bay controller encountered a failure

  • down - bay controller is not in operation.

Max number of historical logging files

Specifies the maximum number of logging files configured for this bay controller.

Bay Controller's CLEI Code

Specifies the Common Language Equipment Identification (CLEI) Code assigned by Telcordia for this bay controller.

Serial Number:

Serial number for the bay controller.

IPriori release version:

Release number for the version of IPriori operating on the bay controller.

Operational image version:

Version number for operational image.

ROM version:

Version number for bay controller boot ROM.

Temperature thresholds (degC)

bay

Critical, Major, and Minor temperature alarms for the bay controller are triggered at the indicated thresholds.

module

Critical, Major, and Minor temperature alarms for the routing modules are triggered at the indicated thresholds.

POWER:

Line [1A - 5B]

Identifies the line for which statistics are being kept. Lines 1A through 4B correspond to the A and B feeds the routing module shelves. Shelf 5 (lines 5A and 5B) is the bay controller shelf.

Breaker

Indicates if the breakers is closed (operational), open (tripped), or not in use (off).

Supply

Indicates the volts supplied to the corresponding shelf.

Status

The status of the line. inSpec means that the line is working within specifications. outSpec means that the power is outside of specifications on this line.

Volts

The number of volts measured on the line. A voltage of 5 indicates that one or more modules has been detected on the shelf. This value is blank for shelf 5.

Status

The status of the voltage. inSpec means that voltage on this line is within specifications. outSpec means that the voltage is outside of specifications. This value is blank for shelf 5.

LINKS:

Ethernet

Indicates if the links between the bay controller and the server are operational.

HDLC

Indicates if the links between the two bay controllers in this bay are operational.

FANS:

Fan [1 - 4]

The identifier of the fan.

Fan's CLEI Code

Specifies the Common Language Equipment Identification (CLEI) Code assigned by Telcordia for the fans.

AdminState

The state to which the fans have been set by an administrator:

  • autonomous - Software control of the fans is disabled.

  • controlled - Software control of the fans is enabled.

OperState

The state in which the fan is actually operating:

  • autonomous - Software control of the fans is disabled.

  • controlled - Software control of the fans is enabled.

  • failed - The fans have failed. Service is required.

RPM

The current speed of the fan in Revolutions per minute.

degC

The ambient temperature of the bay at the fans in degrees C.

LedState

Displays the LED state for each fan.

  • off - power is off or fan is communicating with the bay controller.

  • red - Fan failure is detected. Attention is required.

  • green - power is on, bay controller can not communicate with the fan.

.

Example 2: The following is sample output from the show bay fans command for bay 1

FANS:

Fan's CLEI Code is IPC2U80EAA

Fan AdminState OperState RPM degC LedState

--- ---------- --------- ---- ---- --------

1 controlled controlled 2432 22 off

2 controlled controlled 2432 22 off

3 controlled controlled 2432 21 off

4 controlled controlled 2400 21 off

The following table describes the fields in the display:

Table 3-9. Fields Displayed by show bay fans 

Field Description

FANS:

Fan [1 - 4]

The identifier of the fan.

Fan's CLEI Code

Specifies the Common Language Equipment Identification (CLEI) Code assigned by Telcordia for the fans.

AdminState

The state to which the fans have been set by an administrator:

  • autonomous - Software control of the fans is disabled.

  • controlled - Software control of the fans is enabled.

OperState

The state in which the fan is actually operating:

  • autonomous - Software control of the fans is disabled.

  • controlled - Software control of the fans is enabled.

  • failed - The fans have failed. Service is required.

RPM

The current speed of the fan in Revolutions per minute.

degC

The ambient temperature of the bay at the fans in degrees C.

LedState

Displays the LED state for each fan.

  • off - power is off or fan is communicating with the bay controller.

  • red - Fan failure is detected. Attention is required.

  • green - power is on, bay controller can not communicate with the fan.

Example 3: The following is sample output from the show bay server-registrations command for bay 1:

router#show bay 1 server-registrations

Current Registered Servers

==========================

Server 1

Reg.Time: FRI NOV 03 15:46:11 2000



Lifetime: 19

Num Deaths: 0

Last Event: Registering

Server 2

Reg.Time: FRI NOV 03 15:46:13 2000



Lifetime: 20

Num Deaths: 0

Last Event: Registering

The following table describes the fields in the display:

Table 3-10. Fields Displayed by show bay server-registration 

Field Description

Server 1 | 2

The server ID.

Reg. Time:

The server registration is refreshed every 2 seconds. This timestamp indicates the last time the server was either started or re-registered after losing the refresh.

Lifetime:

The number of tics until the server registration must be refreshed before a timeout is declared.

Num. Deaths:

The number of times the server registration has failed to refresh (timed out).

Last Event:

Last event that occurred in the registration cycle.

Related Commands: show bay controllers
show bay slots
show module
show server
show version


PREV NEXT INDEX

Copyright © 2005 Avici Systems Inc.
Avici® and TSR® is a registered trademark of Avici Systems Inc.
IPriori™, Composite Links™, SSR™, QSR, and NSR® are trademarks of Avici Systems Inc.

   Source File Name: sys_mgmt.fm
    HTML File Name: sys_mgmt42.html
    Last Updated: 02/25/05 at 14:26:49

Please email suggestions and comments to: doc@avici.com