PREV NEXT INDEX

Avici Systems Inc.


fabric link down-event


Modifies the HLTF down-event threshold.

Syntax: fabric link down-event linkName downEventValue

linkName

Specifies the link to apply the down-event value modification:

all - all fabric links

xplus - +X fabric link.

xminus - -X fabric link.

yplus - +Y fabric link.

yminus - -Y fabric link.

zplus - +Z fabric link.

zminus - -Z fabric link.

downEvent
Value

Specifies the down-event value for the named link.

Description: The down-event threshold is the maximum number of down-events that can occur during the time-window period before heuristic places the link into the "failed" state.

Use the fabric link down-event command to modify the down-event threshold.

NOTE It is strongly recommended that you do not change the down-event threshold default values unless you are certain you know what you are doing. The un-necessary taking down of too many links can result in lost system forwarding performance.

Use the show fabric link command to display the status of the six links associated with each module.

Factory Default: 10.

Command Mode: Module configuration.

Example: The following example changes the down-event threshold value for axis X+ to 7 for module 1/5:

router#config terminal

Enter configuration commands, one per line. End with CNTL/Z.

router(config)#module 1/5

router(config-module)#fabric link down-event xplus 7

router(config-module)#end

router#show fabric links mod 1/5



Module 1/5:

Fabric Link To     Admin  Oper   Speed CRC    Events Left/ Down   Time

Destination Module State  State        Errors Max Events   Events Window

------------------ ------ -----  ----- ------ -----------  ------ ------

X+ to Module 3/26  Up     Up     42    0      7/7          0      10

X- to Module none  Up     Failed 42    50     0/10         15     10

Y+ to module none  Up     Down   42    0      10/10        0      10

Y- to module none  Up     Down   42    0      10/10        0      10

Z+ to module none  Up     Down   42    0      10/10        0      10

Z- to module 1/28  Up     Up     42    40     10/10        7      10

Related Commands: fabric link heuristic shutdown
fabric link time-window
show fabric links


PREV NEXT INDEX

Copyright © 2005 Avici Systems Inc.
Avici® and TSR® is a registered trademark of Avici Systems Inc.
IPriori™, Composite Links™, SSR™, QSR, and NSR® are trademarks of Avici Systems Inc.

   Source File Name: Fabric.fm
    HTML File Name: Fabric2.html
    Last Updated: 02/25/05 at 14:31:41

Please email suggestions and comments to: doc@avici.com