clock source
Configures the clock source as internal or line.
Syntax: clock source [internal | line]
[no] clock source
internal
Configures the clock source as internal.
line
Configures the clock source as line.
Description: The clock source command sets the clock source as internal or line on each ATM interface. Each interface must be configured for the same clock source. The clock source must be different than the configured value at the other end of the connection.
Use the no clock source command to reset clock source to the default value.
Factory Default: line.
Command Mode: Interface configuration.
Example: The following example sets the clock source to internal for interface 1/11/3:
router#interface atm 1/11/3
Enter configuration commands, line per line. End with CNTL/Z.
router(config-if)#clock source internal
router(config-if)#end
router#
Related Commands: interface atm
show interface atm
Copyright © 2005
Avici Systems Inc.
Avici® and TSR®
is a registered trademark of Avici Systems Inc.
IPriori, Composite Links, SSR, QSR, and NSR® are
trademarks of Avici Systems Inc.
Source
File Name: ATM.fm
HTML File Name: ATM2.html
Last Updated: 02/25/05 at 14:29:42