clock source


Configures the clock source as internal or line.

Syntax: clock source [internal | line]

[no] clock source

internal

Configures the clock source as internal.

line

Configures the clock source as line.

Description: The clock source command sets the clock source as internal or line on each ATM interface. Each interface must be configured for the same clock source. The clock source must be different than the configured value at the other end of the connection.

Use the no clock source command to reset clock source to the default value.

Factory Default: line.

Command Mode: Interface configuration.

Example: The following example sets the clock source to internal for interface 1/11/3:

router#interface atm 1/11/3

Enter configuration commands, line per line. End with CNTL/Z.

router(config-if)#clock source internal

router(config-if)#end

router#

Related Commands: interface atm
show interface atm